EAPS-270Made in Nandanam, Chennai
Swift EAPS-270 automatic phase changer
Lighting plus seven 1.5-ton ACs, kept on when a phase fails.
- Rated current
- 270 A
- Capacity
- 54 kVA
- Supply
- Three-phase
- Changeover time
- Within 1 s
Price on requestRates change from time to time. We quote on WhatsApp or by phone.

One phase drops. The load carries on.Y's circuits move to a live phase within 1 second.
The Swift automatic phase changer EAPS-270 is rated 270 A, 54 kVA. It suits lighting plus seven 1.5-ton ACs.
When a phase fails, it moves the load to a live phase. This takes less than 1 second. It handles one or two failed phases. When the phase returns, it moves the load back by itself.
Switching is solid-state. It has no transformer, so it can be fitted out of sight. LEDs show the input and output.
Every EAPS-270 carries a serial number and a 3-year warranty. Service is from Chennai.
Fit by a licensed electrician, after the EB meter.
Seven ratings, one range
Other ratings
The same unit in seven ratings, sized by the number of 1.5-ton ACs.
- 1AC1.5-ton, plus lightingEAPS-4040 A · 8 kVA
- 2ACs1.5-ton, plus lightingEAPS-6060 A · 12 kVA
- 3ACs1.5-ton, plus lightingEAPS-9090 A · 18 kVA
- 4ACs1.5-ton, plus lightingEAPS-120120 A · 24 kVA
- 5ACs1.5-ton, plus lightingEAPS-150150 A · 30 kVA
- 6ACs1.5-ton, plus lightingEAPS-180180 A · 36 kVA
- 7ACs1.5-ton, plus lightingEAPS-270270 A · 54 kVAThis model
Datasheet
Specifications
| Rated current | 270 A |
|---|---|
| Capacity | 54 kVA |
| Recommended load | Lighting plus seven 1.5-ton ACs |
| Supply | Three-phase |
| Changeover time | Within 1 s |
| Return to normal | Automatic |
| Switching | Solid-state |
| Transformer | None (transformer-free) |
| Indication | LED, input and output |
| Warranty | 3 years |
| Serial number | On every unit |
Work it out first
Model
EAPS-270
Need a size, a drawing or a wiring question answered? WhatsApp us the model.
Ask on WhatsApp9 questions
Questions buyers ask
01Can the EAPS-270 run seven ACs?
Yes, seven 1.5-ton ACs plus your lighting load. It is rated 270 A, 54 kVA.
02What if I run more than seven ACs?
The EAPS-270 is the largest standard rating. WhatsApp us your full load. We will suggest a setup.
03What if my load is smaller?
Lighting plus six 1.5-ton ACs needs only the EAPS-180. Use the size finder to check.
04One phase is gone. Do I still turn the selector switch?
No. The Swift automatic phase changer moves the load within 1 second. When the phase returns, it moves the load back by itself. You do not need to watch for the power to come back.
05Can I run my AC on it?
Yes. Each rating is sized by 1.5-ton ACs. The EAPS-40 covers lighting plus one AC. The EAPS-270 covers lighting plus seven. Use the size finder to pick yours.
06Will it raise my EB bill?
Your appliances use the same units on any phase. Moving them to a live phase does not add units.
07Does it work on a single-phase supply?
No. It needs a three-phase EB service. Some homes have three-phase supply but single-phase wiring. For those, see the Swift EAPS-SL phase changer.
08What happens if all three phases go?
Then there is no live phase to move to. That is a full power cut. For that, use a generator with a Swift EB-Gen automatic changeover.
09Who services it, and what is the warranty?
We service Swift phase changers in Chennai and all of Tamil Nadu. Service visits are from Chennai. The EAPS carries a 3-year warranty. Service charges depend on the job. WhatsApp us the model on the nameplate. Add a photo of the unit.
Price on request
Ask for a quote
Swift EAPS-270 automatic phase changer: WhatsApp the model and your area, or call. We reply Mon–Sat, 10:00 to 18:00.
Price on requestRates change from time to time. We quote on WhatsApp or by phone.
Also made by Eltech Energy
Related products
EAPS-DBSwift automatic phase changer with DB
The Swift automatic phase changer and your distribution board, in one enclosure.
See details- EAPS-SL
Swift EAPS-SL phase changer for single-phase wiring
Three-phase supply, single-phase wiring: house and UPS stay on a live phase.
See details
EB-GenSwift EB-Gen automatic changeover
EB fails, the load moves to your generator. EB returns, it moves back.
See details